TELUS Spark DIALOG
2015-03-16 12:00
Courtesy of DIALOG
礼貌对话
架构师提供的文本描述。这个13,500平方米项目最具挑战性的方面之一是在有限的预算范围内提供一处令人难忘、青春充沛、充满活力的设施,无论是远距离还是近距离都是如此。为此,该建筑被设想为一个展览平台,里面和外部的通常界限被模糊,随着展品的来来去去,建筑物本身也呈现出新的、五颜六色的形式。
Text description provided by the architects. One of the most challenging aspects of this 13,500 sq m project was to provide a facility that is memorable, youthfully exuberant and dynamic, both from a distance and up-close, within a limited budget. To this end, the building was conceived as an exhibit platform where the usual boundaries of inside and outside are blurred and the building itself takes on new, colourful forms as exhibits come and go.
建筑物的表皮是分层的。信封本身很简单,是一个中立的、高性能的建筑系统,充当展览平台的画布。
The building skin is layered. The envelope itself is simple; a neutral, high-performance building system that acts as the canvas for the exhibit platform.
Courtesy of DIALOG
礼貌对话
在前面的划痕,被剥离在不同的地方周围的建筑物,显示临时展览,图形和艺术作品。当从远处观看时,它将提供丰富的色彩和运动,当仔细观察时,它将提供一个可识别物体和图像的详细框架。广泛的能量建模有助于优化建筑围护结构。
The scrim, in front, is peeled away in different places around the building, revealing temporary exhibits, graphics and artwork. When viewed from a distance it will provide a rich patina of colour and movement and when viewed up close a detailed framework of identifiable objects and images. Extensive energy modeling assisted in optimizing the building envelope and scrim.
First Floor Plan
一层平面图
Telus SPark公司是LEED黄金认证公司,为了符合科学中心的核心价值观,旨在教育和告知游客保护地球的重要性。
Telus Spark is LEED® Gold Certified, and in keeping with the Science Centre’s core values, aims to educate and inform its visitors on the importance of protecting the earth.
Courtesy of DIALOG
礼貌对话
多孔铺路、生物排水、现场保水/再利用和湿地区域与高性能建筑围护结构集成在一起,采用太阳能遮阳、自然光和太阳能屋顶。而不是一个典型的,强制空气通风和冷却系统,该建筑采用置换通风和辐射板,以分配新鲜空气和高效供暖和冷却,以游客的舒适。
Porous paving, bio-swales, on-site water retention/reuse and wetland areas are integrated with a high performance building envelope that uses solar shading, natural light and has a solar ready roof. Rather than a typical, forced-air ventilation and cooling system, the building incorporates displacement ventilation and radiant panels to distribute fresh air and highly effective heating and cooling for visitor comfort.
Second Floor Plan
二层平面图
中庭和广泛的大厅区域采用辐射式冷却/加热板系统加热和冷却,用于非侵入性但高效的空调系统。在剧院内提供座椅下置换通风,以达到最佳的热舒适性和通风效果。
The atrium and extensive lobby areas are heated and cooled with a radiant chilled/heated slab system for a non-intrusive but highly effective conditioning system.Underseat displacement ventilation is provided in the theatre for optimum thermal comfort and ventilation effectiveness.
Architects DIALOG
Location TELUS Spark, 220 Saint Georges Drive Northeast, Calgary, AB T2E 5T2, Canada
Category Science Center
Area 13500.0 sqm
Project Year 2011